TABLE 8 – FIELD CONNECTIONS (Shunt Wound Motors Only)
AC LINE
VOLTAGE
115
115
230
230
230
*Step down operation. See Section 7.2, on page 20.
6.6 Full
Voltage
Connection
Wound Motors Only) –
Connect the motor field
leads to F+ and F-
terminals of TB3 as
shown in Figure 4, and
Table 7, on page 14.
Note: Do not connect
motor armature
leads to F+ and
F- terminals.
CAUTION! Do not use F+
and F- terminals of TB3 for
any purpose other than to
power the field of a shunt
wound motor.
6.7 Half
Voltage
Connection
Wound Motors Only) –
Connect the motor field
leads to F+, TB3 and L1
terminals of TB2, as
shown in Figure 5, and
Table 7, on page 14.
CAUTION! TB3 terminals are
not isolated from AC line. Do
not ground (earth).
Note: Do not connect
motor
leads to F+ and
F- terminals.
FIELD VOLTAGE
(VDC)
90
90
180
180
*90
Field
FIGURE 4 B FULL VOLTAGE FIELD CONNECTION
(Shunt
Field
FIGURE 5 B HALF VOLTAGE FIELD CONNECTION
(Shunt
GND
(EARTH)
armature
FIELD VOLTAGE
(VDC)
100
50
200
100
100
TB2
L1
L2
M2
GND
(EARTH)
AC LINE
ARMATURE
INPUT
See Table 6, for Torque Requirements.
TB2
L1
L2
M2
AC LINE
INPUT
See Table 6, for Torque Requirements.

FIELD CONNECTION

F+, F-
F+, L1
F+, F-
F+, L1
F+, L1
TB3
M1
F+
+
M
-
FIELD
TB3
M1
F+
+
M
-
ARMATURE
F-
F-
FIELD
15