Terminal Block Wiring Information; Field Connections; Ac Line And Armature Connection; Full Voltage Field - KB Electronics Penta Power KBRG-255 Installation And Operating Instructions Manual

Regenerative drive, 5hp, full wave-4 quadrant
Table of Contents

Advertisement

TABLE 4 – TERMINAL BLOCK WIRING INFORMATION
Terminal Block
Designation
TB1 (Power Board)
TB1 (Logic Board)
TB2
*AWG, Cu wire only.
A. AC Line – Connect AC line to
terminals L1 and L2. (See fig
3.)
B. Ground – Be sure to ground
(earth) the control via green
screw located on chassis
C. Motor Armature – Connect
motor armature to terminal M1 and
M2. (See fig. 3)
D. Field (For Shunt Wound motors
only) – Do not use F+ and F-
terminals for any other motor type. Connect motor shunt field to terminals F+ and F- for
180VDC motors with 200VDC fields. For motors with half voltage fields, 180VDC motors
with 100VDC fields, connect field to terminals F+ and L1 (see fig 4A and 4B). See table
5 for summary of Field Connections.
CAUTION – Shunt-Wound motors may be damaged if field remains connected
without motor rotating for an extended period of time. To remove field voltage from
motor, disconnect AC line.
FIG. 4A – FULL VOLTAGE FIELD
TABLE 5 – FIELD CONNECTIONS (Shunt Wound Motors Only)
AC Line Voltage (VAC)
230
230
E. Main Speed Potentiometer – The main speed potentiometer can be connected in several
ways using terminals "10," "11," "12" and "13." ( A 5K ohm potentiometer is supplied with
control. A 10K potentiometer can also be used.) [WARNING: Terminals 10, 11, 12 and
13 are not isolated from AC line. Do not ground (earth).]
i.
Unidirectional operation only – Connect potentiometer to terminals "10," "12," "13" for
forward direction. (To operate in reverse direction, connect to "11," "12," "13.")
Connection
Designation
F+, F-
Logic Connections
L1, L2, M1, M2
Motor Voltage
180
180
Supply Wire Gauge*
Maximu
Minimum
m
22
14
22
14
18
8
FIG. 3 – AC LINE AND ARMATURE VOLTAGE
FIG.4B – HALF VOLTAGE FIELD
Field Voltage (VDC)
200
100
Maximum
Tightening
Torque (lb inch)
7
3.5
16
Field Connection
F+, F-
F+, L1
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8821

Table of Contents