Electrical Ratings; General Performance Specifications - KB Electronics Penta Power KBRG-212D Installation And Operation Manual

Regenerative drive, variable speed scr control full wave 4-quadrant
Hide thumbs Also See for Penta Power KBRG-212D:
Table of Contents

Advertisement

Input Voltage
(VAC)
115
208/230
TABLE 5 B GENERAL PERFORMANCE SPECIFICATIONS
AC Line Input Voltage (VAC, ±10%, 50/60 Hz)
Armature Voltage Range at 115 VAC Line (VDC)
Armature Voltage Range at 230 VAC Line (VDC)
Field Voltage at 115 VAC Line (VDC)
Field Voltage at 230 VAC Line (VDC)
Max Load Capacity (% for 2 Minutes)
Ambient Temperature Range (ºC / °F)
Speed Range (Ratio)
Arm Feedback Load Regulation (% Base Speed)
Tach Feedback Load Regulation (% Set Speed)
AC Line Regulation (% Base Speed)
Current Ranges (Amps DC)
FWD and REV Accel Range (Seconds)
Deadband Range (% Base Speed)
Max Speed Trimpot Range (% Base Speed)
IR Comp Range at 115 VAC Line (VDC)
IR Comp Range at 230 VAC Line (VDC)
FCL and RCL Range (% Range Setting)
Voltage Following Input Range (VDC)
Voltage Following Linearity (% Base Speed)
TABLE 4 B ELECTRICAL RATINGS
Maximum AC
Line Current
(Amps RMS)
12
12
Parameter
Output
Voltage
DC Output
(Volts DC)
Current (ADC)
0 – ±90
0 – ±180
Specification
115 or 208/230
0 – ±90, 0 – ±180
0 – 40 / 32 – 104
1.7, 2.5, 5.0, 7.5
Maximum
Horsepower
7.5
7.5
Factory Setting
0 – ±90
100 / 50
200 / 100
150
50:1
±1
±1
±0.5
0.1 – 15
0 – ±5
55 – 110
0 – 20
0 – 40
0 – 175
±5 – ±25
0 – ±10, 0 – ±15
±0.5
Maximum
HP, (KW)
¾, (0.5)
1.5, (1)
208/230
0 – ±180
7.5
1
0
100
5
10
150
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents