Standard Features; Selectable Jumpers - KB Electronics Penta Power KBRG-212D Installation And Operation Manual

Regenerative drive, variable speed scr control full wave 4-quadrant
Hide thumbs Also See for Penta Power KBRG-212D:
Table of Contents

Advertisement

Feature
Terminal Blocks
(See Section 6, on page 13.)
Connectors
(See Section 7, on page 19.)

Selectable Jumpers

(See Section 7, on page 19.)
Trimpots
(See Section 10, on page 25.)
Diagnostic LEDs
(See Section 11, on page 30.)
TABLE 2 – SELECTABLE JUMPERS (See Section 7, on page 19)
J2-Motor Current, Refer to Section 7.1, on page
19.
J3 – Motor Armature Voltage, Refer to Section
7.2, on page 20.
J5-SPD / TRQ, Speed or Torque, Refer to
Section 7.3, on page 20.
J6-CTS/RTS. Refer to Section 7.4, on page 21.
J8-Signal Input (15V or 10V). Refer to Section
7.5, on page 22.
J17-Signal Input. Refer to Section 7.6, on page
22.
J9-EN (Enable) / INH (Inhibit). Refer to Section
7.7, on page 22.
TABLE 1 – STANDARD FEATURES
Facilitates wiring of AC line, motor armature and field,
TB1 (-15V, +15V, SIG, COM, EN), TB2 (L1, L2, M2, M1), TB3
(F+, F-).
J1, Tach-Generator Input – Connection point for an external
Tach-Generator.
J2 - Motor Armature Current
J3 - Motor Armature Voltage
J5 -SPD / TRQ – (Speed / Torque)
J6 -CTS/RTS – (Coast to Stop / Regenerate to Stop)
J8 -Signal Input Source (15V or 10V)
J9 - Enable (EN) / Inhibit (INH)
J17- Analog Signal Input (Voltage/Current)
Provide adjustment for Forward Acceleration (FACC), Reverse
Acceleration (RACC), Maximum (MAX), Forward Current Limit
(FCL), Reverse Current Limit (RCL), IR Compensation (IR),
Response (RESP), Deadband (DB), Offset (OFFSET), and
Scale (SCALE).
For Power On (ON), and Current Limit (OL) indications.
(Current Overload gives indication that the control will trip).
Feature
Description
Description
For selection of the motor current being used.
For selection of the motor voltage being
used.
Jumper position is selectable for either Speed
(SPD) or Torque (TRQ) modes.
For selection of Coast to Stop (CTS) and
Regenerate to Stop (RTS). Works in
conjunction with the Enable circuit.
Used for selection of potentiometer (15V) or
use if the control is to be used from a
0 – ±10/±15VDC.
Input signal connection for the use with the
Main
Speed
Potentiometer.
accepting a 0 – ±10V or 0 – ±25V signal or
4 – 20 ma.
For selection of electronically starting and
stopping the motor. Used in conjunction with
J6, CTS/RTS.
Used
for
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents