Siemens SINAMICS G120C Getting Started page 31

Frequency converter
Hide thumbs Also See for SINAMICS G120C:
Table of Contents

Advertisement

P-No.
Note
p0323
Maximum motor current [A]
r0330
Rated motor slip
r0331
Actual motor magnetizing current/short-circuit
current
r0333
Rated motor torque [Nm]
p0335
Motor cooling type
p0340
Automatic calculation of motor/control parameters
p0341
Motor moment of inertia [kgm²]
p0342
Ratio between the total and motor moment of
inertia [kgm²]
r0345
Nominal motor starting time
p0346
Motor excitation build-up time [s]
p0347
Motor de-excitation time [s]
p0350
Motor stator resistance, cold [Ω]
p0352
Cable resistance [Ω]
r0395
Actual stator resistance
r0396
Actual rotor resistance
p0500
Technology application
p0505
Selecting the system of units
1
System of units SI
2
Referred system of units/SI
3
US system of units
4
System of units, referred/US
p0573
Inhibit automatic reference value calculation
p0595
Selecting technological units
1
%
3
bar
6
ltr/s
9
m³/min
12 kg/s
15 t/min
18 kN
21 °F
24 gallon/min
27 inch³/h
30 lb/h
33 K
36 m/s
39 BTU/min
42 inch wg
45 % r.h.
SINAMICS G120C frequency converter
Getting Started, 03/2012, FW V4.5, A5E03831830B AA
2
1 referred, no dimensions
4
°C
5
Pa
7
m³/s
8
ltr/min
10 ltr/h
11 m³/h
13 kg/min
14 kg/h
16 t/h
17 N
19 Nm
20 psi
22 gallon/s
23 inch³/s
25 inch³/min
26 gallon/h
28 lb/s
29 lb/min
31 lbf
32 lbf ft
34 rpm
35 parts/min
37 ft³/s
38 ft³/min
40 BTU/h
41 mbar
43 ft wg
44 m wg
46 g/kg
P-No.
Note
p0596
Reference quantity, technological units
p0601
Motor temperature sensor type
0
No sensor
1
PTC warning & timer
2
KTY84
4
Bimetallic NC contact warning & timer
p0604
Motor temperature alarm threshold [°C]
p0605
Motor temperature fault threshold [°C]
p0610
Motor overtemperature response
0
No response, alarm only, no reduction of I
1
Alarm with reduction of I
2
Alarm and fault, no reduction of I
p0611
I2t motor model thermal time constant [s]
p0615
I2t motor model fault threshold [°C]
p0625
Motor ambient temperature [°C]
p0637
Q flux, flux gradient saturated [mH]
p0640
Current limit [A]
p0700
Command source selection
r0720
CU number of inputs and outputs
r0722
CO/BO: CU digital inputs, status
.00
DI 0 (terminal 5)
.01
DI 1 (terminal 6)
.02
DI 2 (terminal 7)
.03
DI 3 (terminal 8)
.04
DI 4 (terminal 16)
.05
DI 5 (terminal 17)
.11
DI 11 (terminals 3, 4) AI 0
r0723
CO/BO: CU digital inputs, status inverted
p0730
BI: CU signal source for terminal DO 0
NO: Terminal 19 / NC: Terminal 18
p0731
BI: CU signal source for terminal DO 1
NO: Terminal 21
r0747
CU, digital outputs status
p0748
CU, invert digital outputs
r0751
BO: CU analog inputs status word
r0752
CO: CU analog inputs input voltage/current actual
AI0 (terminals 3/4)
Commissioning
4.2 Further settings
max
and fault
max
max
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents