Checking Proper Seating Of Carrier Card; Removing A Carrier Card; Installing A Blank Face Plate - Ericsson TANDBERG Television iPlex N20001 Installation Manual

Table of Contents

Advertisement

iPlex Installation and Hardware Specification Guide

Checking Proper Seating of Carrier Card

WARNING
The carrier card is NOT hot swappable. Do not remove or install
the carrier card while the iPlex chassis has power or damage may
occur.
If the carrier card seating is correct, the MCM Active LED will flash orange
shortly (< 5 seconds) after power-on. It will then turn solid orange once the SCM
Active LED turns green. Shortly after turning solid orange, it will turn green.
If the carrier card is not seated properly, the MCM Active LED will remain off or
may be solid yellow (green and orange on at the same time) immediately.
NOTE
Proper seating may not be immediately apparent. Depending on
your configuration, a carrier card could take up to 20 minutes to
completely boot and initialize.

Removing a Carrier Card

WARNING
The carrier card is NOT hot swappable. Do not remove or install
the carrier card while the iPlex chassis has power or damage may
occur.
To remove a carrier card from the iPlex, loosen the captive screws, pull on both
ejector handles simultaneously, and make sure that the ejector handles are free
before pulling out the blade.

Installing a Blank Face Plate

If you have one carrier card and an open carrier card slot on your iPlex chassis, you
must fill the open slot with a blank face plate. To install the blank face plate:
1 Place it in the open slot on the iPlex chassis with the EMI gasketing facing
down.
2 Align the captive screws with the appropriate screw holes on the iPlex chassis
and tighten into place.
65