iPlex Chassis Basic Components
Front Bezel
STATUS
POWER
ONLINE
Front Bezel LEDs
Using the LCD
Interface
iPlex Installation and Hardware Specification Guide
The basic components of the TANDBERG Television iPlex chassis are shown in
the illustrations as follows.
The iPlex front bezel consists of an LCD display and keypad for entering machine
ID and IP addresses, and a series of LEDs that display system status.
ACTIVE
LINK ACTIVE
ALARM
SCM
ETH1
GE 1
MAJOR
MCM
ETH2
GE 2
MINOR
The LEDs on the front panel indicate the following:
Power Green when all power rails are up and within specifications. The LED is
off if the iPlex encounters a power rail failure
Online Green when iPlex completes booting, configured, and in an active state.
Otherwise, the LED is off
SCM Active Orange when booting, green when the iPlex completes booting
MCM Active Flashing orange when idle waiting for the SCM to complete boot-
ing, solid orange when booting, green when the iPlex completes booting
ETH1 Link/Activity Green when the link is established, flickering green when
there is network activity, off when no link is established
ETH2 Link/Activity Green when the link is established, flickering green when
there is network activity, off when no link is established
GE1 Link/Activity Green when the link is established, flickering green when
there is network activity, off when no link is established
GE2 Link/Activity Green when the link is established, flickering green when
there is network activity, off when no link is established
Major Alarm Red when in major alarm state. Off when not in alarm state
Minor Alarm Red when in major alarm state. Off when not in alarm state
The iPlex uses and LCD display with a six-button keypad that enables you to per-
form the following basic system configuration at the iPlex. There are two types of
screens: menu screens and text entry screens.
•
Set date and time
•
Set Flash and TFTP boot
•
Network configuration
•
Syslog configuration
•
Set host name and password
35