Specifications

Approval & Codes
This appliance is certifi ed to ANSI Z21.88-2017/CSA
2.33-2017 American National Standard / CSA Standard
for Vented Gas Fireplace Heaters for use in Canada
and USA, and to CGA 2.17-91 High Altitude Standard in
Canada. This appliance is for direct vent installations.
This appliance complies with CSA P.4.1-15 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas
and Propane Installation Code CAN/CGA-B149.1. Only
qualifi ed licensed or trained personnel should install
this appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70
or the Canadian Electrical Code, CSA C22.1.
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw

*High Altitude Installations

Input ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500
feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas utility
to confi rm.
For installations at elevations above 4,500 feet (1,370 m)
in Canada, please consult provincial and/or local
authorities having jurisdiction.
6
KN
KP
Natural
Propane
0-4,500 feet*
36,000
36,000
19,000
21,000
4.0"
9.5"
5"
11"
10"
14"
DMS#32
DMS#49
51
30
220
160
Supply Gas
Heater engines
2200LKN / 2200RKN are
used with natural gas.
Heater engines 2200LKP
/ 2200RKP are used with
propane gas.
The supply pressure must be between the limits shown
in the Ratings section.
The supply connection is 1/2" NPT male and located on
the on the rear left side of the fi rebox.
A shut-off valve (supplied) is required on the supply line
to isolate the unit during service. See Set-up Gas Supply
section for details.
Conversion Kits
The 2200K LX2 is supplied as natural gas or propane
gas and is fi eld convertible between fuels. See
instructions packaged with the conversion kits for
further information.
Electrical
The 2200K is designed to run on battery power and
does not require an electrical power source to operate
as a heater. However, it requires electrical power to
operate the interior lighting or the optional 1270RBK
Remote Blower Kit.
HeatShift
System
®
The 2200 fi replace MUST be installed with a HeatShift
kit, a convection system that redistributes the warm
air fl ow away from the fi replace opening to a more
desirable location using natural convection, without use
of a fan.
The warm air fl ow may be relocated to a position higher
up the wall, out the sidewalls, or even to another room.
The result is much cooler wall temperatures above the
fi replace opening for locating television, artwork, etc.
Refer to "Appendix D - HeatShift® Installation" on page
72 of this manual.
 WARNING
Please note that the HeatShift Kit MUST be
installed on this appliance!
X