Framing-Minimal - Valor LX2 2200LKN Installation Manual

Direct vent zero clearance gas fireplace
Table of Contents

Advertisement

Planning
 WARNING
Ensure weight of wall above is
NOT carried by the appliance.
Zero
clearance
standoffs
11-1/4"
(285 mm)
5-1/4"
(133 mm)
17"
(432 mm)
11"
(279 mm)
Combustible
framing material
HeatShift plenum or duct plates framing
required (top, front or sides); see instructions
packed with HeatShift kit.
Framing—Minimal
Combustible framing material
except if using HeatShift front
outlet plenums LDK1 or LDK4:
in this case steel stud required
under outlet opening - see
instructions packed with
HeatShift kit
1/2" (13 mm) non-combustible
cement board required.
(May be covered with max. 3/4"
(19 mm) combustible finish).
Combustible projections must
otherwise conform to allowable
mantel projections - see
Clearances to Combustible
Projections section in this manual.
Max. 1-1/4" (32 mm)
thickness combustible
wall finish allowed
20" (508 mm) min.
15