Power and clamping modules

Advertisement

VIPA System SLIO
PS-CM | Manual
HB300E_PS-CM | Rev. 11/28
July 2011

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLIO Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for VIPA SLIO Series

  • Page 1 VIPA System SLIO PS-CM | Manual HB300E_PS-CM | Rev. 11/28 July 2011...
  • Page 2 Copyright © VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to be disclosed or used except in accordance with applicable agreements. This material is protected by the copyright laws. It may not be reproduced, distributed, or altered in any fashion by any entity (either internal or external to VIPA), except in accordance with applicable agreements, contracts or licensing, without the express written consent of VIPA and the business management owner of the material.
  • Page 3: Table Of Contents

    Power modules ............... 2-1 Safety precautions ................2-2 VIPA 007-1AB00 - DC 24V 10A ............2-3 VIPA 007-1AB10 - DC 24V 4A, DC 24V/5V 2A ........2-7 Chapter 3 Clamp modules ............... 3-1 VIPA 001-1BA00 - 8xDC 24V clamps........... 3-2 VIPA 001-1BA10 - 8xDC 0V clamps.............
  • Page 4 Manual VIPA System SLIO Contents HB300E - PS-CM - Rev. 11/28...
  • Page 5: About This Manual

    Overview Chapter 1: Basics and Assembly The focus of this chapter is on the introduction of the VIPA System SLIO. Here you will find the information required to assemble a controller system consisting of System SLIO components. Besides the dimensions the general technical data of System SLIO will be found.
  • Page 6 About this manual This manual describes the System SLIO power modules and clamp Objective and modules from VIPA. It contains a description of the structure, project contents engineering and deployment. The manual is targeted at users who have a background in automation Target audience technology.
  • Page 7: Safety Information

    Manual VIPA System SLIO Safety information Safety information The System SLIO is constructed and produced for: Applications conforming with • communication and process control specifications • general control and automation applications • industrial applications • operation within the environmental conditions specified in the technical data •...
  • Page 8 Manual VIPA System SLIO Safety information HB300E - PS-CM - Rev. 11/28...
  • Page 9: Chapter 1 Basics And Assembly

    Chapter 1 Basics and Assembly Chapter 1 Basics and Assembly The focus of this chapter is on the introduction of the VIPA System SLIO. Overview Here you will find the information required to assemble and wire a controller system consisting of System SLIO components.
  • Page 10: Safety Information For Users

    Manual VIPA System SLIO Chapter 1 Basics and Assembly Safety Information for Users VIPA modules make use of highly integrated components in MOS- Handling of Technology. These components are extremely sensitive to over-voltages electrostatic that can occur during electrostatic discharges.
  • Page 11: System Conception

    Manual VIPA System SLIO Chapter 1 Basics and Assembly System conception System SLIO is a modular automation system for assembly on a 35mm Overview mounting rail. By means of the peripheral modules with 2, 4 or 8 channels this system may properly be adapted matching to your automation tasks.
  • Page 12 Manual VIPA System SLIO Chapter 1 Basics and Assembly Each periphery module consists of a terminal and an electronic module. Periphery modules Terminal module Electronic module Terminal module The terminal module serves to carry the electronic module, contains the backplane bus with power supply for the electronic, the DC 24V power section supply and the staircase-shaped terminal for wiring.
  • Page 13 Manual VIPA System SLIO Chapter 1 Basics and Assembly Accessories Shield bus carrier The shield bus carrier serves to carry the shield bus (10mm x 3mm) to connect cable shields. Shield bus carriers, shield bus and shield fixings are not in the scope of delivery.
  • Page 14: Dimensions

    Manual VIPA System SLIO Chapter 1 Basics and Assembly Dimensions Dimensions bus coupler 76.5 48.5 Dimensions periphery module 76.5 12.9 Dimensions electronic module 12.9 Dimensions in mm HB300E - PS-CM - Rev. 11/28...
  • Page 15: Installation

    Manual VIPA System SLIO Chapter 1 Basics and Assembly Installation There is a locking lever at the top side of the terminal module. For mounting Functional and demounting this locking lever is to be turned upwards until this principle engages audible.
  • Page 16 Manual VIPA System SLIO Chapter 1 Basics and Assembly The modules were directly be mounted to the mounting rail and so Mounting connected to the backplane bus and the power supply for the electronic Proceeding and power section. Up to 64 modules may be mounted. Please consider here that the sum current of the electronic power supply does not exceed the maximum value of 3A.
  • Page 17 Manual VIPA System SLIO Chapter 1 Basics and Assembly • Mounting Mount the periphery modules you want. periphery modules Clack • After mounting the whole system, to protect the backplane bus Mounting the bus cover connectors at the last module you have to mount the bus cover, now.
  • Page 18: Demounting And Module Exchange

    Manual VIPA System SLIO Chapter 1 Basics and Assembly Demounting and module exchange With demounting and exchange of a module, head module (e.g. bus Proceeding coupler) or a group of modules for mounting reasons you have always to remove the electronic module of the just mounted right module. After the mounting it may be plugged again.
  • Page 19 Manual VIPA System SLIO Chapter 1 Basics and Assembly • For mounting turn the locking lever of the module to be mounted upwards. • To mount the module put it to the gap between the both modules and push it, guided by the stripes at both sides, to the mounting rail.
  • Page 20 Manual VIPA System SLIO Chapter 1 Basics and Assembly • For mounting turn all the locking lever of the head module to be mounted upwards. • To mount the head module put it to the left module and push it, guided by the stripes, to the mounting rail.
  • Page 21 Manual VIPA System SLIO Chapter 1 Basics and Assembly • Pull the module group forward. • For mounting turn all the locking lever of the module group to be mounted upwards. • To mount the module group put it to the gap between the both modules and push it, guided by the stripes at both sides, to the mounting rail.
  • Page 22: Wiring

    Manual VIPA System SLIO Chapter 1 Basics and Assembly Wiring Terminals with spring clamp technology are used for wiring. The spring Connectors clamp technology allows quick and easy connection of your signal and supply lines. In contrast to screw terminal connections this type of connection is vibration proof.
  • Page 23 Manual VIPA System SLIO Chapter 1 Basics and Assembly Standard wiring SysDC5V max. 3A DC24V max. 10A DC24V DC24V (1) DC 24V for power section supply I/O area (max 10A) (2) DC 24V for electronic power supply bus coupler and I/O area...
  • Page 24 If the 10A for the power section supply is no longer sufficient, you may use Deployment of the the power module from VIPA with the order number 007-1AB00. So you power modules have also the possibility to define isolated groups.
  • Page 25 Manual VIPA System SLIO Chapter 1 Basics and Assembly To attach the shield the mounting of shield bus carriers are necessary. Shield attachment The shield bus carrier (available as accessory) serves to carry the shield bus to connect cable shields.
  • Page 26: Trouble Shooting - Leds

    Manual VIPA System SLIO Chapter 1 Basics and Assembly Trouble shooting - LEDs Each module has the LEDs RUN and MF on its front side. Errors or General incorrect modules may be located by means of these LEDs. In the following illustrations flashing LEDs are marked by ☼.
  • Page 27: Installation Guidelines

    Manual VIPA System SLIO Chapter 1 Basics and Assembly Installation guidelines The installation guidelines contain information about the interference free General deployment of System SLIO. There is the description of the ways, interference may occur in your control, how you can make sure the electromagnetic digestibility (EMC), and how you manage the isolation.
  • Page 28 Manual VIPA System SLIO Chapter 1 Basics and Assembly In the most times it is enough to take care of some elementary rules to Basic rules for guarantee the EMC. Please regard the following basic rules when installing your PLC.
  • Page 29 Manual VIPA System SLIO Chapter 1 Basics and Assembly Electrical, magnetically and electromagnetic interference fields are Isolation of weakened by means of an isolation, one talks of absorption. conductors Via the isolation rail, that is connected conductive with the rack, interference currents are shunt via cable isolation to the ground.
  • Page 30: General Data

    Manual VIPA System SLIO Chapter 1 Basics and Assembly General data Conformity and approval Conformity 2006/95/EG Low-voltage directive Approval UL 508 Approval for USA and Canada others RoHs Product is unleaded Protection of persons and device protection Type of protection...
  • Page 31: Chapter 2 Power Modules

    System SLIO from VIPA. Content Topic Page Chapter 2 Power modules ............... 2-1 Safety precautions ................2-2 VIPA 007-1AB00 - DC 24V 10A ............2-3 VIPA 007-1AB10 - DC 24V 4A, DC 24V/5V 2A ........2-7 HB300E - PS-CM - Rev. 11/28...
  • Page 32: Safety Precautions

    Manual VIPA System SLIO Chapter 2 Power modules Safety precautions The Power modules were designed and constructed: Appropriate use • to be installed on mounting rail along with System SLIO components • for installation in a cabinet with sufficient ventilation •...
  • Page 33: Vipa 007-1Ab00 - Dc 24V 10A

    Manual VIPA System SLIO Chapter 2 Power modules VIPA 007-1AB00 - DC 24V 10A If the 10A for the power section supply of the I/O area is no longer Description sufficient, you may use the power module. So you have also the possibility to define isolated groups.
  • Page 34 Manual VIPA System SLIO Chapter 2 Power modules For wires with a cross section of 0.08mm up to 1.5mm Pin assignment DC24V DC24V Pos. Function Type Description not connected DC 24V Feed-in DC 24V power section supply Feed-in ground GND...
  • Page 35 Manual VIPA System SLIO Chapter 2 Power modules The following figure shows the standard cabling of the power supply by Deployment means of a bus coupler. SysDC5V max. 3A DC24V max. 10A DC24V DC24V (1) DC 24V for power section supply I/O area (max. 10A)
  • Page 36 Manual VIPA System SLIO Chapter 2 Power modules Technical data Order number 007-1AB00 Type PM 007 Module ID Technical data power supply Input voltage (rated value) DC 24 V Input voltage (permitted range) DC 20.4...28.8 V Mains frequency (rated value)
  • Page 37: Vipa 007-1Ab10 - Dc 24V 4A, Dc 24V/5V 2A

    Manual VIPA System SLIO Chapter 2 Power modules VIPA 007-1AB10 - DC 24V 4A, DC 24V/5V 2A If the 3A for the electronic power supply of the I/O area is no longer Description sufficient, you may use the power module. Additionally the power module serves for a new isolated group for the DC 24V power section supply with max.
  • Page 38 Manual VIPA System SLIO Chapter 2 Power modules For wires with a cross section of 0.08mm up to 1.5mm Pin assignment DC24V DC24V DC24V Pos. Function Type Description not connected DC 24V Feed-in DC 24V power section supply Feed-in ground GND...
  • Page 39 Manual VIPA System SLIO Chapter 2 Power modules The following figure shows the standard cabling of the power supply by Standard wiring means of a bus coupler. SysDC5V max. 3A DC24V max. 10A DC24V DC24V (1) DC 24V for power section supply I/O area...
  • Page 40 Manual VIPA System SLIO Chapter 2 Power modules Technical data Order number 007-1AB10 Type PM 007 Module ID Technical data power supply Input voltage (rated value) DC 24 V Input voltage (permitted range) DC 20.4...28.8 V Mains frequency (rated value)
  • Page 41: Chapter 3 Clamp Modules

    Content Topic Page Chapter 3 Clamp modules ............... 3-1 VIPA 001-1BA00 - 8xDC 24V clamps........... 3-2 VIPA 001-1BA10 - 8xDC 0V clamps............. 3-4 VIPA 001-1BA20 - 4xDC 24V and 4xDC 0V clamps......3-6 HB300E - PS-CM - Rev. 11/28...
  • Page 42: Vipa 001-1Ba00 - 8Xdc 24V Clamps

    Manual VIPA System SLIO Chapter 3 Clamp modules VIPA 001-1BA00 - 8xDC 24V clamps This clamp module is a "potential distributor module". The DC 24V of the Description power section supply may be accessed by 8 clamp connectors of the terminal.
  • Page 43 Manual VIPA System SLIO Chapter 3 Clamp modules For wires with a cross section of 0.08mm up to 1.5mm Pin assignment DC24V Pos. Function Type Description DC 24V DC 24V power section supply DC 24V DC 24V power section supply...
  • Page 44: Vipa 001-1Ba10 - 8Xdc 0V Clamps

    Manual VIPA System SLIO Chapter 3 Clamp modules VIPA 001-1BA10 - 8xDC 0V clamps This clamp module is a "potential distributor module". The ground GND of Description the DC 24V power section supply may be accessed by 8 clamp connectors of the terminal.
  • Page 45 Manual VIPA System SLIO Chapter 3 Clamp modules For wires with a cross section of 0.08mm up to 1.5mm Pin assignment DC24V Pos. Function Type Description DC 0V Ground GND power section supply DC 0V Ground GND power section supply...
  • Page 46: Vipa 001-1Ba20 - 4Xdc 24V And 4Xdc 0V Clamps

    Manual VIPA System SLIO Chapter 3 Clamp modules VIPA 001-1BA20 - 4xDC 24V and 4xDC 0V clamps This clamp module is a "potential distributor module". The DC 24V Description respectively ground GND of the power section supply may be accessed by 4 clamp connectors each of the terminal.
  • Page 47 Manual VIPA System SLIO Chapter 3 Clamp modules For wires with a cross section of 0.08mm up to 1.5mm Pin assignment DC24V Pos. Function Type Description DC 24V DC 24V power section supply DC 24V DC 24V power section supply...
  • Page 48 Manual VIPA System SLIO Chapter 3 Clamp modules HB300E - PS-CM - Rev. 11/28...