7
Teach-in
NOTICE!
Interference in function
Teach-in while the system is running may result in
malfunctions.
► Stop the system before performing teach-in.
Initial situation:
Transducer with magnet within measuring range
1. Activate teach-in
► Activate
a
for at least 4 s.
2. Set null point
► Bring magnet to the new null point.
► Activate
a
for at least 2 s.
⇒ The new null point is set after activation.
3. Set end point
► Bring magnet to the new end point.
► Activate
for at least 2 s.
b
⇒ The new end point is set after activation.
4. End teach-in
► Briefly activate
a
and
⇒ Current position value is displayed.
Any of the individual steps for settings can be
selected. The teach-in process can be ended at
any time.
14
english
simultaneously (< 1 s).
b
LED legend:
LED display Displayed values (example)
LED
a
> 4 s
a
> 2 s
b
> 2 s
a
b
< 1 s
LED green
LED red
At 0...10 V
At 4...20 mA
5.39 V
9.15 mA
5.39 V
9.15 mA
1.04 V
4.82 mA
0.00 V
4.00 mA
9.89 V
19.13 mA
10.00 V
20.00 mA
LED flashing green

Advertisement