Specifications - Allen-Bradley Kinetix 5700 Series Installation Instructions Manual

Regenerative bus supply
Hide thumbs Also See for Kinetix 5700 Series:
Table of Contents

Advertisement

Kinetix 5700 Regenerative Bus Supply

Specifications

Attribute
Surrounding air temperature
Operating
Storage
Weight, kg (lb) approx
Short-circuit current rating
Branch-circuit short-circuit
protection
• Kinetix 5700 drives produce leakage current in the protective-earthing conductor that exceeds 3.5 mA AC and/
or 10 mA DC. The minimum size of the protective-earthing (grounding) conductor used in the application must
comply with local safety regulations for high-protective-earthing conductor current equipment.
Leakage
current
• Kinetix 5700 drives produce DC current in the protective-earthing conductor and can reduce the ability of a
residual current device (RCD) or residual current monitor (RCM) of type A or AC to provide protection for the
drive module and other equipment in the installation.
18
2198-RP088
0...50 °C (32...122 °F)
-40...70 °C (-40...158 °F)
13.6 (30)
200,000 A rms symmetrical
Integral solid-state short circuit protection does not provide branch circuit protection. Branch
circuit protection must be provided in accordance with the National Electric Code (NEC) and any
additional local codes.
Rockwell Automation Publication 2198-IN014A-EN-P - August 2018
2198-RP200
2198-RP263
38.6 (85)
61.2 (135)
2198-RP312
61.2 (135)