Kinetix 5700 Regenerative Bus Supply

Catalog Number Explanation

This publication applies to the following Kinetix 5700 regenerative bus supplies.
Regenerative Bus Supply Catalog Numbers
Regenerative Bus Supply
Cat. No.
2198-RP088
2198-RP200
2198-RP263
2198-RP312
(1) Applies when DC-bus voltage regulation is enabled. If DC-bus voltage regulation is not enabled, then the input voltage range is 324....528V AC.
For more information on these two modes of operation, see the Kinetix 5700 Servo Drives User Manual, publication 2198-UM002.

Before You Begin

Prepare all equipment and hardware that is used to lift the regenerative bus supply before you
unpack and lift the module out of the shipping container.
Parts List
The Kinetix 5700 regenerative bus supplies include the following accessory items:
• DC-bus end caps
• Wiring plug connector set for mains input power (IPD), 24V control input power (CP),
digital inputs (IOD), shunt power (RC), and contactor enable (CED)
• Wiring plug connector for shunt power (RC) connections installed on the module
TIP
Replacement connector sets (catalog numbers 2198-KITCON-RP088, 2198-KITCON-RP200, and
2198-KITCON-RP312) are also available. See the Kinetix Servo Drives Specifications Technical Data,
publication KNX-TD003, for more information.
• These installation instructions, publication 2198-IN014
2
Module
Width
Input Voltage
mm
165
275
324...506V AC rms,
three-phase
440
Rockwell Automation Publication 2198-IN014A-EN-P - August 2018
Continuous
(1)
Output Power
kW
24
67
119
140
Continuous
Output Current
A
rms
DC
35
100
176
207