T T a a b b l l e e 4 4 - - 2 2 S S p p e e c c i i a a l l P P r r o o g g r r a a m m m m i i n n g g P P r r o o c c e e d d u u r r e e s s
Menu Step
SP-1 Fahrenheit/
1 1 . . "TEMP, UNITS", along with "°F" or "°C" shows in display.
Celsius
2 2 . . Press the up or down button to change the temperature unit.
3 3 . . Press the program button to continue onto SP-2 Lock/Unlock.
SP-2 Lock/
1 1 . . "LOCK/UNLOCK PROGRAMMING" shows in display, along with
Unlock
"LOCK" or "UNLOCK".
2 2 . . Press the up or down button to toggle between locking or unlocking
the programming.
3 3 . . Press the program button to continue onto SP-3 Air Temperature
Setpoint.
SP-3 Air Tem-
1 1 . . "AIR TEMP SETPOINT", and the preset cabinet temperature show in
perature
the display.
Setpoint
2 2 . . Press the up or down button to change the air temperature setpoint;
140°F (60°C) minimum, 210°F (99°C) maximum.
3 3 . . Press the program button to continue onto SP-4 Humidity Setpoint.
SP-4 Humidity
1 1 . . "HUMIDITY SETPOINT", and the preset humidity setpoint show in
Setpoint
display.
2 2 . . Press the up or down button to change the humidity setpoint; 0% to
90%.
3 3 . . Press the program button to continue onto SP-5 Out of Water Trip
Point.
SP-5 Out of
1 1 . . "OUT OF WATER TRIP POINT" and the preset trip point
Water Trip Point
temperature show in the display. If the float switch fails, the trip point
temperature is the water pan temperature at which the control
senses the water pan is out of water. We recommend a trip point
temperature of 450°F (232°C).
2 2 . . Press the up or down button to change the out-of-water trip point.
3 3 . . Press the program button to continue onto SP-6 Clean Water Pan
Setpoint.
SP-6 Clean
1 1 . . "CLEAN WATER PAN SETPOINT" and the preset temperature, at
Water Pan
which the control senses that the water pan needs cleaned of lime,
Setpoint
show in the display. We recommend a setpoint temperature of 425°F
(218°C).
2 2 . . Press the up or down button to change the setpoint.
3 3 . . Press the program button to continue onto SP-7 System Initialization.