Specifications - Hengstler tico 732 User Manual

Bidirectional multifunction-counter
Table of Contents

Advertisement

7. Specifications

Counter,
Batch counter,
2-Shift counter
Tachometer
Time-counter
Ambient Conditions /
Safety Regulations
24/28
Display
Digit height
Supply voltage
Tolerances
Current consumption
Overload protection
Sensor supply
Data retention
Electrical connection
Mounting
Amplitude thresholds
Active edge
Pulse shape
Input resistance
Counting frequency
Prescaler
Count inputs A, B
Pulse length min.
Control Input C
Relay
Transistor
Count mode
Response time
Alarms
Time bases
Resolution
Function
count mode
Operating Temperature
Storage Temperature
Protection Class
Vibrostability
Shock stability
General Rating
Climatic Standards
Contamination level
EMC-Noise immunity
EMC-Emission
LED or LCD, 6 digits, leading zero suppression, decimal
point
LED 7,6 mm; LCD 9 mm
12...24 VDC or 24 VAC; 100 VAC; 115 VAC; 230 VAC; 50/60 Hz
± 10%
12...24 VDC < 150 mA
24 VAC < 250 mA; including sensor supply
100/115/230 VAC < 50 mA; including sensor supply
ext. fuse DC: 0,16 AT/IEC 127; DC: 0,2 AT/UL 198
24 VAC: 315 mAT
230 VAC: 32 mAT; 115/100 VAC: 63 mAT
only when AC operated: 12...30 VDC, max 50 mA
non-volatile memory > 10 years
screw terminals
with clamping frame, panel thickness max. 11mm
< 2 V and > 8 V or < 2 V and > 3.8 V with TTL-Level, max 40 VDC
programmable; positive with pnp input; negative with
npn input
any (squarewave 1:1 for max. frequency)
approx. 10 kOhm (static)
max. 5 kHz (2.5 kHz bi-directional); with the accessory totalizer
switched on, the count frequency is diminished by approx. 10%
Multiplier programmable from 0,001 to 999,999
- phase discriminator with single evaluation
- differential mode (add/sub)
- count direction mode
- totalizing mode (add/add)
17 ms (30 Hz), 100 µs (5 kHz)
- manual reset possible
- external reset, static or dynamic, programmable,
pulse length > 5 ms
- automatic reset when main preset has been reached
(programmable)
changeover contact max. 250 VAC / 30 VDC, min. 5 V AC/DC
max. 1 A, min. 10 mA, delay < 5 ms
pnp output 12...24 VDC; max 10 mA with DC supply
pnp output
12...30 VDC; max 10 mA with AC supply
period measurement
Display and outputs are checked every 500 ms (f>2 Hz);
If f<2 Hz, there is an update at the end of each period
2 alarms with programmable start-up-suppression
programmable; sec, min., h
or in display format HH:MM:SS
programmable 1; 0,1; 0,01; 0,001
single pulse measurement (short time meter) or
cummulated counting (hour meter)
pulse width or period measurement (start-stop)
0°C ... 50 °C
- 20 °C ... + 60°C
front side IP 65 (EN 60529)
2
10 m/s
(10...150 Hz) according to IEC 68-part 2-6
2
100 m/s
(18 ms) according to IEC 68- part 2-27
according VDE 0411, DIN 57411, EN 61010, protection class II
DIN 40 040: 40/92 °C/% relative air humidity; KWF
2, according to VDE 0110
EN 50082-2
EN 50081-2
Sach-Nr. 2 732 017; Version 1310301WBI

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents