Programming Of Functioncodes - Hengstler tico 732 User Manual

Bidirectional multifunction-counter
Table of Contents

Advertisement

4.2
Programming of functionscodes
Programming mode:
press while
switching
Power on
function
basic settings
time unit
resolution
reset/setmode
signal time
output 1
signal time
output 2
time counter mode
Output in case of
reset
pnp/npn-
selection
input
attentuation
dyn./static
Reset
output
signal memory
additional
totalizer
Stop after main
preset reached
keylock for
reset key 6+4
keylock for preset 1
keylock for preset 2
keylock mode for
(F20-F23)
* default values
1
2
with appliances with one preset only, this applies to preset 1 and output 1 (OUT 1)
3
4
5
14/28
Change parameter:
press
code alternatives/signification
F0
0*
1
F2
0*
1
2
3
F3
0*
1
2
3
F4
0*
1
2
3
1
F6
OFF
On
0,02
0,05
0,10*
0,20
0,50
1,00
F7
1
see
above
F8
0*
1
2
3
F9
0*
1
F10
0
1*
2
3
F11
0
1*
F12
0*
1
F14
0*
1
F15
0*
1
F16
0*
1
F20
0*
1
F21
1
0*
1
1
F22
0*
1
F29
0*
1
parameter only appears for preset version
counting as long as Input A is active (see example 1)
counting starts and stops with the leading edge (see example 2).
with every start signal the counter starts again from zero
Change to the next function:
press
no function
all function codes are set to the *-marked values
seconds
minutes
hours
format HH.MM.SS
no decimal point
one decimal place (xxxxx.x); 0.1 time unit
two decimal places (xxxx.xx); 0.01 time unit
three decimal places (xxx.xxx); 0.001 time unit, F 2 = 0, solution in msec
reset to „0", no autoreset
reset to „0", with autoreset when reaching preset 2
6
set to preset 2
, no autoreset
6
set to preset 2
, with autoreset when reaching „0"
no Output signal
bistable Output signal, will be deleted by Out 2
20 ms
50 ms
100 ms
200 ms
500 ms
1 s
see above; signal time output 1
cumulated counting with pulse width measurement
cumulated counting with period measurement
5
single counting
with pulse width measurement
single counting
5
with period measurement
Output from main preset (OUT 2)
by reset
Output from main preset (OUT 2)
npn with 8V level (negative)
pnp with 8V level (positive)
npn with TTL-level
pnp with TTL-level
30 Hz attenuation (for contacts)
no attentuation, 5 kHz
(bidirectional counting: 2,5 kHz)
static reset
dynamic reset (counting possible during reseting)
after power fail, the signal times will not be
restarted
after power fail, the signal times will be restarted
disabled
enabled
no stop after main preset reached
stop after main preset reached
irrespective of measurements
key reset is possible
key reset is not possible (or possible with delay
see F29)
access to preset 1 is possible
access to preset 1 is not possible (or delayed see F29)
access to preset 2 is possible
access to preset 2 is not possible (or delayed see F29)
access to parameters from F20-F22 is possible after
holding the keys for more than 10 sec.
access to parameter is not possible
Return to count mode:
press > 5 s e c
6
3
4
3
4
2
is not activated
2
is activated by reset
1
Sach-Nr. 2 732 017; Version 1310301WBI