Programming Of Functioncodes - Hengstler tico 732 User Manual

Bidirectional multifunction-counter
Table of Contents

Advertisement

6.2 Programmieren der Batchzähler-Funktionscodes
Programming mode:
press while
switching
Power on
function
basic settings
count mode
decimal point
(on display)
reset/setmode
signal time
output 1
signal time
output 2
Output in case of
reset
pnp/npn-
selection
input
attentuation
dyn./static
Reset
output
signal memory
external Reset
signal
Batchcounter/
2 Totalizer
keylock for
reset key 6+4
keylock for preset 1
keylock for preset 2
keylock for prescaler
keylock mode for
(F20-F23)
* default values
1
bidirectional counting with single evaluation (e.g. for encoders with 2 channels A,B)
2
parameter only appears for preset version
3
Input B passive (0V at PNP or 24V at NPN or open)
Input B active (24V at PNP or 0V at NPN)
Sach-Nr. 2 732 017; Version 1310301WBI
Change parameter:
press
code alternatives/signification
F0
0*
no function
1
all function codes are set to the *-marked values
F1
Input A
0*
count Input
1
count Input
2
count Input
3
adding
4
adding
5
adding
6
channel A
7
channel A
F3
0*
no decimal point
1
one decimal place (xxxxx.x
2
two decimal places (xxxx.xx)
3
three decimal places (xxx.xxx
F4
0*
reset to „0", no autoreset
1
reset to „0", with autoreset when reaching preset 2
2
set to preset 2, no autoreset
3
set to preset 2, with autoreset when reaching „0"
F6
2
OFF
no Output signal
On
bistable Output signal, will be deleted by Out 2
0,02
20 ms
0,05
50 ms
0,10*
100 ms
0,20
200 ms
0,50
500 ms
1,00
1 s
2
F7
see
see above; signal time output 1
above
F9
0*
Output from main preset (OUT 2) is not activated
by reset
1
Output from main preset (OUT 2) is activated by reset
F10
0
npn with 8V level (negative)
1*
pnp with 8V level (positive)
2
npn with TTL-level
3
pnp with TTL-level
F11
0
30 Hz attenuation (for contacts)
1*
no attentuation, 5 kHz
(bidirectional counting: 2,5 kHz)
F12
0*
static reset
1
dynamic reset (counting possible during reseting)
F14
0*
after power fail, the signal times will not be restarted
1
after power fail, the signal times will be restarted
F15
0*
resets only the counter
1
resets only the batch counter
F16
0*
Batchounter
1
2 Totalizer with preset value
F20
0*
key reset is possible
1
key reset is not possible (or possible with delay
see F29)
2
F21
0*
access to preset 1 is possible
1
access to preset 1 is not possible (or delayed see F29)
2
F22
0*
access to preset 2 is possible
1
access to preset 2 is not possible (or delayed see F29)
F23
0*
access to prescaler is possible
1
access to prescaler is not possible (or delayed see F29)
F29
0*
access to parameters from F20-F23 is possible after
holding the keys for more than 10 sec.
1
access to parameter is not possible
Count direction negative
Change to the next function:
press
Input B
Input C
gate
reset
3
direction(u/d)
reset
3
direction(u/d)
gate
subtracting
reset
subtracting
gate
adding
reset
1
1
channel B
reset
1
1
channel B
gate
Count direction positive
Return to count mode:
press > 5 sec
21/28