Scope of work

Three center aligned Pulse Width Modulated (PWM) signals with fixed
frequency and different duty cycles are generated using CCU6.
The code example uses the Timer T12 of CCU6 and its three compare
modules to generate three PWM signals with a frequency of 20 kHz and
different duty cycles (25%, 50% and 75%). T12 is configured to count up and
down and the three signals are center aligned.
The generated PWM signals are sent to the pins available on the board and
can be observed with an oscilloscope.