Connecting Output Signals; Output Circuit - Contec DIO-0808L-PCI User Manual

Digital i/o board for pci
Table of Contents

Advertisement

Connecting Output Signals

Connect the output signals to a current-driven controlled device such as a relay or LED.
The connection requires an external power supply to feed currents.
The board controls turning on/off the current-driven controlled device using a digital value.

Output Circuit

Vcc
Opto-coupler
Opto-coupler
* O-xx represents the output pin.
Figure 3.5. Output Circuit
The signal output section is an opto-coupler isolated, open-collector output (current sink type). Driving
the output section requires an external power supply.
The rated output current per channel is 100mA at maximum.
The output section can also be connected to a TTL level input as it uses a low-saturated transistor for
output. The residual voltage (low-level voltage) between the collector and emitter with the output on is
0.5V or less at an output current within 50mA or at most 1.0V at an output current within 100mA.
A zener diode is connected to the output transistor for protection from surge voltages. A Fuse-based
overcurrent protector is provided for every 8 output transistors. When the overcurrent protector works,
the output section of the board is temporarily disabled. If this is the case, turn of the power to the PC and
the external power supply and wait for a few minutes, then turn them on back.
CAUTION
When the PC is turned on, all output are reset to OFF.
DIO-0808L-PCI
Board
Plus
common
Output
pin
Zener
diode
Output
pin
Zener
diode
Fuse
Minus
common
External circuit
Load
External
power supply
12 - 24VDC
Load
3. External Connection