4

Handling

4.1

Transport

• Climate category: 2K3 according to EN 60721
• Transport temperature: -25 °C - +70 °C, max. fluctuation 20 K/hour
• Transport humidity: relative humidity 5% - 95%, non-condensing
• The servomotor may only be transported by qualified personnel and in the manufacturer's original
recyclable packaging.
• Avoid hard impacts, particularly at the shaft end.
• If the packaging is damaged, check the motor for visible damage. Inform the transport company and, if
necessary, the manufacturer.
4.2

Packaging

• The max. stacking height by the servo motors AM8100 is 10 cardboard packaging.
4.3

Storage

• Climate category
• Storage temperature:
• Air humidity:
• Max. stacking height:
• Storage time:
• Store only in the manufacturer's original recyclable packaging
4.4

Maintenance / Cleaning

• Maintenance and cleaning only by qualified personnel.
• The ball bearings have a grease filling with a service life of 30,000 hours under normal operating
conditions. The bearings should be replaced after 30,000 hours of operation under rated conditions.
• Check the motor for bearing noise every 2,500 operating hours or once per year. If any noises are
heard, stop the operation of the motor. The bearings must be replaced.
• In motors with optional shaft seal ring the ring must be lubricated every 5,000 hours. We recommend
TM
„Mobilgrease
FM 222" from Mobil.
• Opening the motor invalidates the warranty.
• Clean the housing with isopropanol or similar.
• Never immerse or spray the servomotor.
4.5

Disposal

In accordance with the WEEE 2012/19/EU Directives we take old devices and accessories back for
professional disposal, provided the transport costs are taken over by the sender.
Send the devices with the note "For disposal" to:
Beckhoff Automation GmbH & Co. KG
Huelshorstweg 20
D-33415 Verl
Synchronous servomotor
2K3 according to EN 60721
-25 °C - +70 °C, max. fluctuation 20 K/hour
relative humidity 5% - 95%, non-condensing
see table Packaging
without limitation
Version: 2.1
Handling
11

Advertisement

Table of Contents
loading

Table of Contents