8.4. OVERVIEW

DIAGNOSTIC MESSAGES
Code
Diagnostic
message
D1
Water Level
Sensor
D2
Temperature
Sensor
D3
Service Due
D4
Door Sense Fault
D5
Coin 1 Drop Blck
D6
Door Unload
D7
Slow Fill Detect
D8
Slow Drain
Detect
D9
-
D10
Dr Lock Sense
D11
Motor Speed Err
D12
Motor Sense Flt
D13
Coin 2 Drop Blck
D14
Door Start
D15
Overfill
D16
Comm Debt Crd
Flt
D17
Door Fail Lock
D18
Memory Err
D19
Softw Err
D20
Tilt Fault
D21
Imbalance
D22
Tilt High Spin
D23
-
D24
-
38
Failure
Action
Defective level sensor
Continue + Don't start
Continue + Don't start
Defective temperature
sensor
Service Due Warning
Symbol For Info only
Door switch failure
Full stop + safety time
Don't start
Coin Drop 1
Blocked
Don't start
Door lock switch
closed failure
Fill failure
Full stop + tumble
Drain failure
Skip + Continue
-
-
Full stop + safety time
Door solenoid switch
failure
(*)
(**)
Don't start
Coin Drop 2
Blocked
Don't start
Door lock check at
start failure
Overfill failure
Full stop + tumble
No Debit Card Reader
Don't start
Communication
Bimetal/Spring
Continue
Memory Error
Full stop + safety time
Software Error
Full stop + safety time
Out of balance :
Full stop + tumble
Before spin
Out of balance :
Skip + continue
Normal spin
Out of balance : high
Full stop + safety time
spin
-
-
-
-
PROGRAMMING MANUAL
Fault occurrence
Before start up
Before start up
End cycle
Whole cycle
At start up
End cycle
While filling
Draining sequence
-
Whole cycle
At start up
At start up
While filling
At start up
Check 2 min after start cycle
Any time
Any time
Start spin
After 10 x tilt
>500 or 750 RPM
-
-
516532 B
PUBLICATION DATE 1 JUN 2007.DOC