How To Handle Fault Messages - Maytag MFS Series Programming Manual

Table of Contents

Advertisement

8.3. HOW TO HANDLE FAULT MESSAGES

ATTENTION !!!
!
CHECK IN THE MANUAL FOR WHAT PROBLEM THE DIAGNOSTIC OR HELP CODE CORRESPONDS
TO. ASK THE ASSISTANCE OF AN EXPERIENCED TECHNICIAN TO SOLVE THE PROBLEM.
ALL THE SAFETY PRECAUTIONS MUST BE FOLLOWED BEFORE EACH INTERVENTION.
You can overrule and erase fault messages by:
pressing the ENTER button (key switch in Service – Set-Up mode)
switching the power off/on
opening the door (D3 and D21)
For safety reasons the door will not be unlocked if :
- there is still water in the drum
- the water temperature is above 130°F
- the drum is still turning (a safety time will be respected until the drum comes to a standstill)
- there is a problem with the door lock system
Each time at the end of the cycle, the Graphic Control Wash computer will fulfil a safety test
sequence.
If at the end of the cycle the safety conditions are not fulfilled, the messages TOO HOT or
WATER IN CAGE will be displayed.
If the problem disappears (the water has dropped below the safety level for spin or the water temperature
has dropped below 130°F) the Error message TOO HOT or WATER IN CAGE will disappear automatically.
ATTENTION !!!
!
IT'S UP TO THE OPERATOR TO TAKE THE NECESSARY PRECAUTIONS IF THE DRAIN VALVE IS
NOT FUNCTIONAL AND IF THERE IS STILL HOT WATER IN THE TUB AT THE END OF THE WASH CYCLE.
ON THE DISPLAY THE ACTUAL WATER TEMPERATURE AND LEVEL WILL BE DISPLAYED.
WAIT UNTIL THE WATER IS DRAINED AND UNTIL THE WATER HAS COOLED BEFORE ALL
INTERVENTIONS AS HOT WATER CAN CAUSE SEVERE BURNS.
CARE MUST BE TAKEN THAT NOBODY GETS BURNED DUE TO HOT WATER.
DEPENDING THE FAILURE TYPE THE MCG WASH COMPUTER WILL START A SPECIFIC
PROCEDURE :
WHEN SAFETY IS INVOLVED
Full stop + tumble
Full stop + safety time
Don't start
36
TOO HOT
XX°F
: the program is stopped but will run the tumble sequence
: the program is stopped and a safety time is started
: the program will not be started as long as the safety
conditions are not fulfilled
PROGRAMMING MANUAL
WATER IN CAGE
XX°F LEVEL YY
516532 B
PUBLICATION DATE 1 JUN 2007.DOC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents