INSTALLATION GUIDE (NEW OEM INSTALLATIONS ONLY)
1. The installation consists of mounting the display inside the RV, cutting and
fastening the senders to the sides of the holding tanks, connecting wiring,
and programming the display.
2. Mount the display by cutting a hole in the wall 3" wide by 1 7/8" high and
bringing the wiring out through the hole to connect to the display panel
connector.
3. Connect the wiring according to the following table. It is easier to connect
the wiring to the display connector first, and then plug the connector into
the display panel. The sender needs to be grounded to a single ground
wire from the display.
Wire Color
Red 18 gauge
Black 18 gauge
Blue 18 gauge
Yellow 18 gauge
Green 18 gauge
4. Determine where to mount the senders on the tanks. They will need to
have a flat area on the side of the tank large enough so the whole width of
the sender is in contact with the side of the tank, all the way from the top to
the bottom of the tank. Make sure that any metal is at least an inch away
from the sender. Clean the area well so that there is no dust, grease, oil,
water, etc., that would prevent the adhesive on the sender from sticking.
5. Measure the height of the tank to determine how long the senders should
be. For tanks less than 7" tall, follow step 6. For tanks from 7" to 13" tall,
follow step 7. For tanks greater than 13" tall, follow step 8.
6. For tanks less than 7" tall, a single short sender is used. The sender ends
should be 1/4" to 3/4" away from the top and bottom of the tank, to allow for
the thickness of the tank top and bottom and any bows in them (see the
diagrams). The senders are calibrated to account for this distance from
the bottom of the tank. The sender is cut to the nearest even 1 inch in
length, for example, a system with a tank height of 5.75 inches, cut the
sender to be 5 inches long, this allows 3/8" at each end when the sender is
centered vertically on the tank. IMPORTANT: Do not cut the sender
shorter than 4 inches! The sender will not work if it is cut less than 4
inches. Proceed to step 9.
CHAPTER 6
+12V power input to monitor
Ground
Tank senders
Pump power output
LPG tank (optional)