If a sender or its wiring is not operating properly, the following codes are
shown on the display:
1.
If a sender is unresponsive or there is an open circuit in the wiring so that
the sender is not connected, the display will indicate the open circuit
code. If a sender is shorted or there is an short in the wiring, the display
will indicate the short circuit code.
2.
If a sender is sending bad data, there is damaged wiring, or if there is
electrical interference, the display will indicate the data error code. Also,
if the senders have not been programmed correctly, they can interfere
with one another and result in a data error. Check all the senders to
make sure they are programmed correctly. If they are, replace the
sender that is creating the error.