display matches with the number of senders connected, otherwise the
display will show an error.
2.
To enter the sender programming mode, press and hold down the button
for the tank to be programmed, the display will show a level or an error
message.
3.
While continuing to hold down the button for the tank, press and hold
down the BATT button. The display will immediately show the
diagnostics code, continue to hold down both buttons until the display
enters the number of senders programming mode, this should take about
5 seconds. When the programming mode is entered, release both
buttons.
4.
The display will now show the code for one sender or two senders, based
on what is currently programmed into the display. These are the only two
options, the display will not work with more than two senders per tank.
5.
To change the number of senders, press the tank button, each time the
button is pressed the display will switch to the other number.
100%
15V
75%
14V
50%
13V
25%
12V
0%
11V
Diagnostics
100%
15V
75%
14V
50%
13V
25%
12V
0%
11V
One sender
100%
15V
75%
14V
50%
13V
25%
12V
0%
11V
Number
of senders
100%
15V
75%
14V
50%
13V
25%
12V
0%
11V
Two senders