12 Loading the factory settings
Before you configure the device to its factory settings, you should note the following:
• Save your configuration first. After restoring the factory settings, all of your settings/
changes will be deleted.
• The IP address of the device is reset to the original IP address (192.168.0.100).
• You may also need to modify the network settings of the configuration PC accordingly.
• The device password is reset to its individual default password. The default password
can be found on the back of the unit.
• No USB stick/storage medium should be connected to the device.
Execution:
1. Switch on the mbNET or press the Reset button.
2. Wait until the LED Rdy flashes green.
3. Press and hold the Dial Out button until LED Fc4 is lit.
4. Press the Dial Out button again => LED Fc3 lights up.
5. Repeat step 4. => LED FC2 lights up.
6. Press the Dial Out => button one last time, after approximately 10 - 20 sec.
LED Fc3 flashes.
When both the Pwr and Rdy LEDs light up, the mbNET is reset to its „factory settings at the
time of delivery" and can/must be reconfigured.