Horizontal Terminations
-5/8"
Rigid Pipe 4" x 6
The minimum components required for a basic horizontal termination
are:
1 Power Vent Kit
1 Rigid Pipe Adaptor
1 Vent Reducer
1 Length of pipe to suit wall thickness and total vent run
(see Table 1)
Wall thickness is measured from the back standoffs to the inside mounting
surface of termination cap. Create a level surface to mount the vent terminal.
The T erminal must not be recessed into siding. Measure the wall thickness.
Flat Wall Installation
Wall Thickness
(inches)
4" - 5-1/2"
7" - 8-1/2"
10" - 11-1/2"
9" - 14-1/2'
15" - 23-1/2"
Table 1
Vent Length Required
(inches)
6"
9"
12"
11" - 14-5/8" Adj. Pipe
17" - 24" Adj. Pipe
Adj.Pipe Length
90 Elbow
o
Pipe Length
Vent reducer
(Part #946-606)
Rigid Pipe Adapter
installation
Powervent Kit
(Part #946-535)
City Series CB72EPV |
59