installation
Clearances - Corner Install
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
fireplace and vent system be installed only in accordance with these instructions.
Note: Left handed corner shown in illustration. Clearances will be the same for the right hand side.
Clearance: single sided
A: Mantel Height (min.)
B: Opening Height
C: From Floor
D: Sidewall (on one side)
E: Mantel Depth (Max.)
F: Alcove Depth
G: Convection Air Outlet
H: Convection Air Outlet Opening Offset
I: Chase Enclosure (Min.)
Hearth
See mantel clearances chart in this manual.
**
I
D
| City Series CB72EPV
32
Dimension
**
Top of Fireplace Opening
15-1/16" (383mm)
Bottom/Top of Fireplace Opening
Min. 0"
Bottom of Fireplace Opening
Min. 26" (660mm)
Side of Fireplace Opening
**
Front of Fireplace Opening
Min. 36" (914mm)
Front of Fireplace Opening
288 square inches
0-2" (51mm)
Max. offset from top of chase enclosure
87" (2210mm)
From Base of Unit/Floor to top of enclosure
0"
No hearth required
F
H
G
E
A
B
C
F
Left Corner
Shown
Top View
Measured From:
D
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
Alcove
Flue Clearances to Combustibles
Horizontal - Top
Horizontal - Side
Horizontal - Bottom
Vertical
Passing through wall/
floor/ceiling - when
firestop is used.
The HeatWave Duct Kit has differ-
ent clearance and framing require-
ments, check the HeatWave manual
for details.
Caution Requirements
WARNING
3"
2"
2"
2"
1-1/2"