installation
CB72 CORNER
3. Bend tabs closest to the finishing trim inwards 90 degrees on the outer
side panel.
L
4. Loosen screws using offset screwdriver and remove trim guides from
side of unit and recycle them.
920-068
| City Series CB72EPV
38
R
2
5. Slide outer side panel down onto screws that remain from removable
trim. Tighten screws with offset screwdriver.
6. Screw in the two self-tapping screws to the top of the outer side panel.
Unit can be placed in framing at this point.
7. See inner panel install section. Once firebox panels are installed, then
install corner conversion liner panel inside of side barrier glass. Note:
Gasket side of panel sits against the glass and the flange sits at top.