Blade Guards; Emergency Stop Button; Electric System - 3M -Matic 7000r Instructions And Parts List

Random case sealer with accuglide 3 taping heads
Hide thumbs Also See for 3M-Matic 7000r:
Table of Contents

Advertisement

10-SAFETY DEVICES OF THE MACHINE

10.1 Blade Guards

Both the top and bottom taping units have a blade
guard. (See Manual 2 or 3: AccuGlide™ 3 Taping
Heads - 2 Inch or 3 Inch).
WARNING
• To reduce the risk associated with sharp
blade hazards:
− Keep hands and fi ngers away from tape
cutoff blades under orange blade guards.
The blades are extremely sharp.

10.2 Emergency Stop Button

The electrically driven box drive belts and pneumatics
are turned on and off with the switch on the side of the
machine frame.
- The machine electrical supply can be turned off by press
ing the latching emergency stop switch (Figure 10-1).
- To restart machine, rotate the emergency stop switch
clockwise to release the switch latch.
Restart machine by turning the On/Off switch to the Off
position and then to the On position (Figure 10-2).
- Then press the Station "Start" Button (Figure 10-3) .
WARNING
To reduce the risk associated with
hazardous voltage:
Position electrical cord away from foot
and vehicle traffi c.
7000r-7000r3 Pro - NA
E-Stop
"On-Off"
Figure 10-1

10.3 Electric System

The electric system is protected by a ground wire
whose continuity has been tested during the fi nal
inspection. The system is also subject to insulation
and dielectric strength tests.
To reduce the risk associated with
mechanical and electrical hazards:
− Allow only properly trained and qualifi ed
personnel to operate and service this
equipment.
Note: The case sealer has a circuit breaker
located in the electrical enclosure on the
machine frame. If circuit becomes overloaded
and circuit breaker trips, unplug the machine
electrical cord and determine cause of
overload. After two minutes, reset the circuit
breaker. Plug machine electrical cord into
outlet and restart machine by Turning the
On/Off switch to the On position.
Important: The use of an extension cord is not
recommended. However, if one is
needed for temporary use, it must:
• Have a wire size of 1.5mm diameter [AWG 16]
• Have a maximum length of 30.5m [100 ft]
• Be properly grounded.
Figure 10-2
36
WARNING
"Start/Stop"
Figure 10-3
2014 June

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3m-matic 7000r3 pro

Table of Contents