CAUTION
Hydraulic oil can get HOT!
ALWAYS allow hydraulic oil to cool before
removing the fill cap. NEVER remove the fill
cap when the oil is hot or spillage will occur.
3. If the hydraulic oil level is low, remove the hydraulic
oil filler cap (Figure 17) and add hydraulic oil up to a
level midway between the MIN and MAX lines on the
reservoir. DO NOT overfill. Use only Parker DuraClean
ISO 46 hydraulic oil. Replace the cap when finished.
FUEL
DANGER
Gasoline fuel is highly flammable and can be
dangerous if mishandled.
NEVER smoke while refueling. NEVER attempt to refuel
while the engine is hot or running.
1. Make sure the trowel is on a secure, level surface with
the engine stopped.
2. Visually inspect the fuel level in the tank (Figure 18).
FUEL
TANK
Figure 18. Fuel Level Inspection
3. If fuel is low, remove the fuel filler cap (Figure 18) and
fill the tank with unleaded 87 or 89 octane gasoline.
DO NOT overfill. The fuel tank holds 4 gallons (15 liters)
of gasoline.
LD6 RIDE-ON POWER TROWEL • OPERATION MANUAL — REV. #0 (02/10/20) — PAGE 27
FUEL
FILLER CAP
DANGER
Fuel spillage on a hot engine can cause
a fire or explosion. If fuel spillage occurs,
wipe up the spilled fuel completely to
prevent fire hazards. NEVER smoke
around or near the trowel.
4. Replace the fuel filler cap when finished adding fuel.