VisuNet GXP
VisuNet GXP
System Installation
Mechanical Installation
Wall Mounting
1. See the VisuNet GXP
2. Install the bracket to the wall.
3. Connect the PE wire from the field to the PE stud on the wall bracket (See figure 3.10
below).
4. Mount the VisuNet GXP to the bolts on the wall bracket. Follow the relevant steps required
for mounting the housing to a pedestal. See chapter 3.3.3
5. With the DPU hinged down, route cables through the cable glands in the wall bracket.
A cable tie socket could be used to attach the cables.
Cables can be routed from the top through the cutout in the wall bracket or from the
bottom.
6. Close the housing. See chapter 3.3.11
Figure 3.10
1
PE stud
Note
Grounding the AG-XX00 Housing to the Wall Bracket
The AG-XX00 housing is grounded indirectly via the wall bracket. It does not require an
additional PE wire between housing and wall bracket.
33
Mounting Options
Note
Always consider the allowed bending radii. See the VisuNet GXP TCU/PCU
manual for information about wiring the TCU/PCU.
1
Bottom view of wall bracket
datasheet for the hole pattern.