VisuNet GXP
Technical Specifications
Mechanical specifications
Degree of protection
Material
Installation
Mass
Dimensions
International approvals
UL approval
IECEx approval
Standards
Zone 1/21
Data for application in connection with hazardous areas
EU-type examination certificate
Directive conformity
Directive 2014/34/EU
Zone 2/22
Data for application in connection with hazardous areas
EU-type examination certificate
Directive conformity
Directive 2014/34/EU
IP66 (individual components and entire system with housing)
Internal:
Panel: anodized aluminum (TCU, PCU, PSU), powder coated
aluminum (DPU)
External:
Bezel: stainless steel AISI 304 (1.4301) System housing: stainless
steel AISI 304
(1.4301), beat blasted, typical surface roughness Ra = 0.8 µm
Flush-mount installation (requires customized mounting kit)
Panel-mount installation into system housing with bezel
Panel-mount installation into cabinet with Bezel and standard
mounting kit
Zone 1/21:
Panel (DPU with bezel, TCU, PSU DC): appx. 23 kg
Panel (DPU with bezel, TCU, PSU AC): appx. 24 kg
Zone 2/22:
Panel (DPU with bezel, TCU, PSU DC): appx. 17.5 kg
Panel (DPU with bezel, TCU, PSU AC): appx. 18 kg
Panel with DC: 625 mm x 459 mm x 120 mm
Panel with AC: 625 mm x 459 mm x 137 mm
Panel with system housing: 625 mm x 459 mm x 173 mm
Panel cut-out: 583 mm x 417 mm (installation surface)
E492874
IECEx BVS 17.0029X
IEC 60079-0:2011, IEC 60079-5:2015, IEC
60079-7:2015, IEC 60079-11:2011, IEC
60079-31:2013
BVS 17 ATEX E 036 X
EN 60079-0:2012+A11:2013, EN 60079-
5:2015, EN 60079-7:2015, EN 60079-
11:2012, EN 60079-31:2014
BVS 17 ATEX E 037 X
EN 60079-0:2012+A11:2013, EN 60079-
5:2015, EN 60079-7:2015, EN 60079-
11:2012, EN 60079-31:2014