System Installation
Mechanical Installation
Warning!
Risk of electric shock or property damage from inadequate grounding.
If you do not ground the device correctly, this could result in potential equalization currents.
These currents could hurt operating personnel or cause property damage.
Ground the device via the grounding bolt. Optionally, ground the device additionally via the
terminal X1.1. When both are used, ensure that a correct potential equalization is guaranteed
at all times.
Note
Refer to the manuals of the individual components for more information on electrical installation
and wiring.
Grounding the AG-XX00 Housing to PEDESTAL-XX00-*.
1. Connect the pre-installed PE wire on the pedestal to the PE stud on the AG-XX00 housing.
2. Ground the pedestal with the PE stud on the bottom plate of PEDESTAL-XX00-*.
3. Fasten the hardware with a torque of 7.5 Nm.