Initial Configuration via Serial Console

To configure the B050-000 via serial interface, both a serial port replicator cable and a null modem cable are required
(available separately). Using a serial terminal, the B050-000 has a serial line interface (on the rear). This connector is
compliant with the RS 232 serial line standard. To establish a serial connection, use a standard null modem cable. The serial
line has to be configured with the parameters given in Table 4-2. When configuring with a serial terminal, reset the B050-
000 and immediately press the "ESC" key. You will see a "=>" prompt. Enter "config", press "Enter" and wait for a few
seconds for the configuration questions to appear.
As you proceed, the following questions will appear on the screen. To accept the default values, which are shown in square
brackets below, press "Enter".
IP auto configuration (non/dhcp/bootp) [dhcp]:
IP [192.168.1.22]:
Net mask [255.255.255.0]:
Gateway (0.0.0.0 for none) [0.0.0.0]:

Web Interface

IP Autoconfiguration:
With this option you can specify whether the B050-000 should get its network settings from a DHCP or
BOOTP server. For DHCP, enter "dhcp", and for BOOTP enter "bootp". If you do not specify any of these, the IP
autoconfiguration is disabled and subsequently you will be asked for the following network settings.
IP Address:
The IP address the B050-000 uses. This option is only available if IP autoconfiguration is disabled.
Net Mask:
The net mask of the connected IP subnet. This option is only available if IP auto- configuration is disabled.
Gateway Address:
The IP address of the default router for the connected IP subnet. If you do not have a default router, enter 0.0.0.0.
This option is only available if IP autoconfiguration is disabled.
4. Configuration
Parameter
Bits/second
Data bits
Parity
Stop bits
Flow control
Table 4-2. Serial Line Parameters
21
Value
115200
8
no