6.2) LOGIC MENU (logic. )
- TCA (TCA) [ OFF ]
ON
Activates automatic closing
OFF Excludes automatic closing
- 3 Steps (3 step) [ OFF ]
ON
Enables 3-step logic. A Start impulse has the following effects:
door closed:..............................................................................opens
on opening: ...............................stops and enters TCA (if configured)
door open: .............................................................................. closes
on closing: ............................................................stops and reopens
OFF Enables 4-step logic. A Start impulse has the following effects:
door closed: ..............................................................................opens
on opening: ...............................stops and enters TCA (if configured)
door open: .............................................................................. closes
on closing: ................................stops and does not enter TCA (stop)
after stopping: ...........................................................................opens
- Impulse lock (ibl open) [ OFF ]
ON
The Start impulse has no effect during the opening phase.
OFF The Start impulse becomes effective during the opening or closing
phase.
- Rapid closing (fast cls) [ OFF ]
ON
Closes the gate after photocell disengagement, before waiting for the
end of the TCA set.
OFF Command not entered.
- Photocell test (test phot) [ OFF ]
ON
Activates photocell check
OFF Deactivates photocell check
If this setting is not activated (OFF), it inhibits the photocell checking
function, allowing connection of devices not provided with additional
checking contact.
- Gate-open or 2nd radio channel warning light (SCA 2ch) [ OFF ]
ON
The output between terminals 21 and 22 is configured as Gate-open warn-
ing light, in this case the 2nd radio channel controls pedestrian opening.
OFF The output between terminals 21 and 22 is configured as 2nd radio
channel.
- Prealarm (preal) [ OFF ]
ON
The blinker turns on about 3 seconds before the motors start.
OFF The blinker turns on about 3 seconds before the motors start.
- Motors in operation (1 mot ON) [ OFF ]
ON
Only motor 2 is in operation (terminals 5, 6 and 7).
With this configuration, the pedestrian input is disabled.
OFF Both motors are in operation.
- Lock hold (block persist) [ OFF ] (Fig. 5)
ON
To be used when the mechanical closing backstop is fitted.
This function activates leaf pressure on the mechanical backstop, without
this being considered as an obstacle by the Ampere-stop sensor.
Therefore the rod continues its travel for another 0.5 sec. after detect-
ing the closing limit switch or upon reaching the mechanical backstop.
So by activating the closing limit switches slightly earlier, the leaves
will come to a perfect halt against the backstop. (Fig. 5a)
OFF To be used when no mechanical closing backstop is fitted.
Movement is exclusively halted by activation of the closing limit
switches; in this case proceed to carrying out precise setting of the
closing limit-switch activation. (Fig. 5b)
- hold-to-run control (hold-to-run) [ OFF ]
ON
Hold-to-run operation: the manoeuvre continues as long as the control
key is kept pressed.
WARNING!: Enabling the Hold-to-run logic entails a different use of
the START and PEDESTRIAN buttons:
START takes on the hold-to-run OPEN function
PEDESTRIAN takes on the hold-to-run CLOSE function
OFF Impulse operation, according to the 3 or 4 step logic.
- Fixed code (fixed code) [ OFF ]
(Advanced logics ⇒ address 13)
ON
The receiver is configured for operation in fixed-code mode, see
paragraph on "Radio Transmitter Cloning".
OFF The receiver is configured for operation in rolling-code mode, see
paragraph on "Radio Transmitter Cloning".
- Radio transmitter programming (radio prog) [ ON ]
(Advanced logics ⇒ address 15)
ON
This enables transmitter storage via radio:
1 – First press the hidden key (P1) and then the normal key (T1, T2,
T3 or T4) of a transmitter already memorised in standard mode by
means of the radio menu.
2 – Within 10s press the hidden key (P1) and the normal key (T1, T2,
T3 or T4) of a transmitter to be memorised.
The receiver exits the programming mode after 10s, other new trans-
mitters can be entered before the end of this time.
14 - NETTUNO B - Ver. 05
INSTALLATION MANUAL
This mode does not require access to the control panel.
OFF This disables transmitter storage via radio.
The transmitters can only be memorised using the appropriate Radio menu.
6.3) RADIO MENU (RADIO)
-
Add
Allows you to add one key of a radio control device to the receiver memory;
after storage it displays a message showing the receiver number in the
memory location (from 01 to 64).
Add Start button (add start)
associates the required key to Start command
Add 2ch button (add 2ch)
associates the required key to 2nd radio channel
-
Read (read)
Checks one key of a receiver; if stored it displays a message showing
the receiver number in the memory location (from 01 to 64), and the key
number (T1, T2, T3 or T4).
-
Eliminate list (erease 64)
WARNING! Completely removes all memorised radio control devices
from the receiver memory.
-
Receiver code reading (RX code)
This displays the code entered in the receiver (par. 11).
Consult paragraphs 8, 9, 10 and 11 for further information concerning
the advanced functions of the Clonix incorporated receiver.
6.4) LANGUAGE MENU (language)
Allows you to set the language on the display programmer.
-
ITALIAN (ITA)
-
FRENCh (FRA)
-
GERMAN (DEU)
-
ENGLISh (ENG)
-
SPANISh (ESP)
6.5) DEFAULT MENU (default)
Restores the preset default values on the control unit. After restoring, a new
autoset operation must be carried out.
6.6) AUTOSET MENU (autoset)
Allows you to automatically set the Motor torque.
WARNING!! The autoset operation is only to be carried out after checking the
exact leaf (opening/closing) movement, and correct limit-switch activation.
As soon as the OK pushbutton is pressed, the ".... ...." message is displayed,
and the control unit executes an opening manoeuvre followed by a closing
manoeuvre, during which the minimum torque value needed for leaf move-
ment is automatically set.
During this phase, it is important to avoid obscuring the photocells, as well
as using the START, STOP or PED commands and the display.
Upon completion of this operation, if the auto-setting is successful, a mes-
sage indicating "OK" will be displayed on the control unit which will return to
the Auto-setting menu after pressing the OK key.
If, on the other hand, the control unit displays the "KO" message, it means
that the autoset procedure has not been successfully completed; it is thus
necessary to check the wear condition of the gate and the regular movement
of the leaves before proceeding to a new autoset operation.
WARNING! During the autoset phase, the obstacle detection function is
not active, therefore the installer must control the automation movement
and prevent persons and things from approaching or standing within the
automation working range.
In the case where buffer batteries are used, autosetting must be carried out
with the control panel supplied by mains power voltage.
WARNING: Check that the impact force value measured at the
points established by the EN 12445 standard is lower than that
specified in the EN 12453 standard.
Incorrect sensitivity setting can cause injuries to persons or
animals, or damage to things.
6.7) MENU' FAST NET (FAST NET)
After all connections have been carried out correctly (Fig. 3), it is necessary
to configure the FAST NET for the identification of the connected devices.
The FAST NET configuration for the identification of the connected devices
should be repeated whenever the connected devices are changed (e.g. by
adding or eliminating some of them).
- Find (find)
Press OK to perform identification of the devices.
show the EEpr message and then a counter checking the network scan-
ning; once it reaches 255, FAST NET scanning is finished and the display
will show the sequence of the devices recognised.
respond to the devices actually connected.
The display will first
Check that they cor-