Remove Cover; Figure 2-18: Tightening Hard Plumbing; Figure 2-19: Cables Secured Out Of Beam Path - NORTHROP GRUMMAN Iklwa II TEM00 Service Manual

Green laser
Table of Contents

Advertisement

Remove Cover

© 2019 Cutting Edge Optronics

Figure 2-18: Tightening Hard Plumbing

10. Connect the coaxial BNC RF cable to the RF driver.
11. Secure coaxial cable and the humidity sensor cable to the hard plumbing lines.

Figure 2-19: Cables Secured Out of Beam Path

NOTE:
Gloves must be worn while servicing the laser. Service must be performed in a
clean room environment.
1. Blow debris off outside of laser housing and cover using nitrogen or Class 0
dry air.
2. Wipe the housing clean using TechniCloth™ wipes and isopropyl alcohol.
3. Remove the fasteners and lift the cover from the laser housing.
4. Do not remove the o-ring from the top groove of the laser housing.
Chapter 3: Tuning and Testing Procedures
28
Patara II and Iklwa II Service Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Patara ii tem00

Table of Contents