Chapter 2: Laser Component Replacement
Procedures

Align HeNe to Optic

© 2016 Cutting Edge Optronics
NOTE:
Gloves must be worn at all times during service. Service procedures must be
performed in a clean room environment when the cover is removed.
1. Mount HeNe at least 2 meters from the laser housing HR or HM access port.
See Figure 1-1. The HR access port is the plug on the front of the laser
housing. The HM access port is the screw below the J1 connector on the rear
of the laser housing.
2. For HR alignment, remove the pin hole from location 1. For HM alignment,
remove the pin hole from location 4. See Figure 1-2.
3. Mark the location of the HeNe reflection from the mirror. The replacement
optic will be aligned to this reference point.