Chapter 1: General Instructions
 Power Meter (minimum 30W rating)
 Camera System (Spiricon preferred)
 Fused silica 3% wedge
 Filter Wheel
 0.391 meter focal length lens PLCX-50.8-180.3-UV-1064/532
 Fast Photodiode with BNC cable and oscilloscope (100 MHz min)
 Neg Lens part number PLCC-25.4-25.8-UV-1064/532
 HeNe alignment laser and turn mirrors
 Microscope with surface illumination
 60-658-1 Alignment Aperture without Alignment Pin
 Desiccant cartridge NG part no. 42-228
 Desiccant Refill part number 643665
 Desiccant Refill tool 980412
 McMaster Disposable Tube-Fitting Filter part no. 4795K22
 McMaster Female QD part no. 5012K83
 McMaster ¼" Hose part no. 52375K32
 McMaster 3/16" Hose part no. 52375K31
 Male QD O-Rings #011 Black Viton (2 required)
 Output Window O-Rings #020 Black Viton (2 required)
 8" Nylon clear cable ties
 Side cutters
 3M 2216 two part epoxy
 X-ACTO Knife

Alignment Reference, Test Set-up and Laser Layout

If possible, the laser should be referenced to a HeNe (or similar alignment laser)
prior to any modifications to the laser. The ideal testing and tuning set-up is
shown in Figure 1-1. The layout and location of the laser components are shown
in Figure 1-2.