2.2 Assembling the remaining thread monitor
Fig. 7: Assembling the remaining thread monitor (1)
(1) - Cable RFW sensor
(2) - Sensor block
(3) - Hose
To assemble the remaining thread monitor:
1. Shorten the hose (3) to a length of approx. 130 mm.
2. Shorten the hose (4) to a length of approx. 400 mm.
3. Connect hose (3) and hose (5) using the plug nipple (4).
4. Insert hose (3) at the sensor block (2).
12
Assembling the remaining thread monitor (1-needle machines)
①
②
③
④
⑤
(4) - Plug nipple
(5) - Hose
Additional Instructions M-TYPE DELTA - 00.0 - 08/2019