DURKOPP ADLER M-TYPE DELTA Additional Instructions page 12

Remaining thread monitor rfw
Table of Contents

Advertisement

Fig. 4: Assembling solenoid valve and RFW PCB (3)
(3) - Solenoid valve
(9) - Holder
(10) - Cable RFW sensor
(11) - Cable
(12) - Cable
10. Tilt the machine head.
11. Remove the dummy plate from the valve block (13).
Information
The valve block and the corresponding connectors and hoses are
included in the pneumatic small parts pack (part number: 0867 594304).
12. Screw the solenoid valve (3) in at the available space on the valve
13. If not yet present, tighten valve block (13) and bracket (14) using
14. Connect the hose (16) to the compressed air maintenance unit.
15. Tighten the holder (9) to the base plate using the screws (17).
10
Assembling the remaining thread monitor (1-needle machines)
block (13).
the screws (15).
Make sure to lay the hose (16) such that it will not be pinched when
the machine head is erected.
(13) - Valve block
(14) - Bracket
(15) - Screws
(16) - Hose
(17) - Screws
Additional Instructions M-TYPE DELTA - 00.0 - 08/2019

Advertisement

Table of Contents
loading

Table of Contents