2.7

Remaining thread monitor

1
The remaining thread monitor monitors the left and right hook thread
bobbin with the infrared reflected light barriers 1 and 2.
2
When the bobbin is empty, the light beam transmitted by the light
barrier 1 or 2 is reflected by the exposed reflecting surface 3 of the
bobbin hub.
The display of the control box shows the message
"Empty bobbin".
The pocket opening is safely finished with the thread in the reserve
groove of the bobbin hub.
The transport carriage stops in its rear end position.
Caution: Danger of injury!
Switch the main switch off.
Clean the lenses of the light barriers only with the sewing unit
switched off.
Switch the main switch off.
Clean the lenses of the light barrier with a soft cloth after every
bobbin change.
Switch the main switch on.
Start a new sewing cycle.