  • Page 1 F210S Optical Device Installation instructions and warnings Istruzioni ed avvertenze per l’installatore Instructions et avertissements pour l'installateur Anweisungen und Hinweise für den Installateur Instrucciones y advertencias para el instalador Instrukcje i ostrzeżenia dla instalatora Aanwijzingen en aanbevelingen voor de installateur...
  • Page 2: Product Description And Applications

    89/336/EEC “Electromagnetic Compatibility” • The use of F210S which is not explicitly provided for in Directive and subsequent modifications 92/31/EEC and these instructions is not permitted. Improper use may 93/68/EEC: This product has been subjected to tests regard- cause damage and personal injury.
  • Page 3: Installation

    • Make sure that the F210S photocell can be used on the motor or control unit to which it is to be connected. If in doubt, con- tact the Nice technical assistance for clarification.
  • Page 4 3.3 “Electrical connections”. 3.3) Electrical connections The power supply and communication of the F210S comes through the TTBUS connection of the motor or control unit. The connection is not polarized, use a cable with a minimum section or 0.5 mm2 and no longer than 30 m.
  • Page 5 3.3.1) Typical connection example (complete) Figure 9 shows a complete connection example of the F210S device with the use of a pressure sensitive device and 3 inde- pendent buttons for the opening, closing and stop of the automation. 3.3.2) Connection example with Step-by-Step control If a Step-by-Step (open-stop-close-stop) control of the automation is sufficient, the connection shown in figure 10 can be made, placing the OPEN and CLOSE inputs in parallel.
  • Page 6 11. To check the optical presence detector (type D) of the in particular chapters 1 “Warnings” and 3 “Installation” is F210S photocell, and to make sure that there is no inter- fully abided by. ference with other devices, pass a 5 cm diameter cylin- 2.
  • Page 7: Additional Information

    This chapter looks at particular actions or programming related to F210S. 5.1) F210S signals and status The status and functioning of the F210S photocell are indicated by the DL1 and DL2 LEDs. Recognising the type of signal can be useful to distinguish faults or resolve possible problems.
  • Page 8: Maintenance

    The following must be performed if the photocell needs to be permanently disconnected from the system: With the F210S photocell connected and the power supply on, remove jumper JP1 from the RX, the DL2 LED will begin to rap- idly flash. At this point turn off the power supply and disconnect the F210S photocell from the TTBUS.
  • Page 9: Technical Characteristics

    9) Technical characteristics In order to improve its products, NICE S.p.a. reserves the right to modify the technical characteristics at any time without prior notice. In any case, the manufacturer guarantees their functionality and fitness for the intended purposes. Note: all technical characteristics refer to a temperature of 20°C.