4 Commissioning
4.5 Acyclic data
PNU
PNU
Parameter number in
Index
Subindex
specific device
DA1
626
0
P7-07
1
P1-06
2
P6-10
3
627
0
C-18
630
0
P5-07
1
P8-13
634
0
P2-27
635
0
P2-26
650
2
62
Access right
DC1
DE1
RUN/
STOP
RUN
P-06
P-06
RUN
RUN
P-31
RUN
RUN
RUN
RUN
RUN
P-33
RUN
P-19
RUN
DX-NET-SWD... 08/14 MN04012009Z-EN www.eaton.com
Data type
Name
ro/rw
rw
WORD
EnhancedGenerator
Control
rw
WORD
EnergyOptimizer
rw
WORD
PLC operation enable
rw
OvervoltageControl
rw
Fan Control
rw
FieldbusRampControl
rw
WORD
Ramp mode
rw
U16
Standby mode
rw
WORD
Spin start enable
rw
DI3 Logic
Description
Advanced generator control
0: deactivated 1: activated
If the energy optimization is
activated, the output voltage
will be adjusted
automatically based on the
load. This will result in a
reduced voltage when
operating within partial load
ranges, reducing energy
consumption levels. This
operating mode is not
suitable for dynamic
applications with quickly
changing loads.
PLC operation enable
0: Deactivated
1: Activated
The overvoltage control
function prevents the drive
from switching off when the
motor is feeding
regenerative power back. If
the function is disabled, the
drive will switch off when
there is an overvoltage signal
instead of automatically
lengthening the ramp time.
Ramp via field bus
0: Deactivated
1: Activated
Ramp selection when there
is a preset speed
0: Deactivated
1: Activated
Standby time
0 = Disabled
150 ≙ 15.0 s
Rotary start enable/DC
injection at enable
0: Deactivated
1: Activated
DE1 only:
This parameter defines the
logic for input 3 when
parameter P-27 is set to 1, 3,
5, 7, or 9 (external fault).