8
8.5
Sheet fall time (only in single sheet mode)
The sheet fall time can be entered here. Enter in msec.
8.6
Shingling
Overlapping in the shingled stream can be adjusted in the shingling menu item. The values
can be varied from 40% - 90%. At 40%, the products will overlap 40%.
8.7
Stop
The stop time can be adjusted proportionally until the interruption in the shingled steam is
sufficient for the pressing rails to extend. Values can be set at 10% to 150%. Default value
75%.
8.8
Amount of folding errors
The number of recognised folding errors at which the machine will stop can be entered here.
0 = switched off.
8.9
Load default values
Default values are loaded by entering 1.
8.10
Tolerance
All products are measured by the delivery's infeed photocell. Now, extra tolerance to the
reference value, which is measured by the calibrate key, can be entered in 0.1 mm. Products
which exceed this value + the tolerance value are ejected via the waste sheet deflector.
8.11
Jogging time
The jogging frequency can be adjusted here. The set time in msec. units corresponds to one
full phase.
8.12
Jogging motor
Jogging can be adjusted if required. The lower the value, the slower the jogging frequency.
All joggers, back joggers and side joggers are simultaneously set with this adjustment.
8.13
Pre-collection finger delay (not active on the delta705)
In the working position, extension of the pre-collection finger can be delayed with this
adjustment. Adjustment depends on the product and the speed. The greater this value, the
later the pre-collection finger retracts