FUSE (1600/1800E)

Two 15 amp fuses protect the control and fil-
ter circuits.
1. See ACCESS FOR SERVICE.
2. With needle nose pliers, disconnect
wire(s) from one end of fuse holder (4).
3. Check between two terminals of fuse
holder with an ohmmeter. Meter
should indicate a closed circuit. If not,
fuse may be faulty.
Fuse Replacement:
1. Remove end cap (5) and replace fuse
(6).
Manual #13898 2/00
HEATING ELEMENTS
(1600/1800E)
All elements heat the oil when solid state
controller calls for heat. If HEAT ON light is
illumminated for long periods of time, this
may indicate a faulty element or wire con-
nection.