Code128
• If you have disabled the auto convert function, enter a two-digits start code at the beginning of the data. If
you have enabled the auto convert function, the type of start character is automatically determined and you
do not need to specify the type in your application.
∗ An error will occur if you add {A, which sets the type to CODE A, when CODE A has already been selected as the start
character.
∗ An error will occur if you add {B, which sets the type to CODE B, when CODE B has already been selected as the start
character.
∗ An error will occur if you add any one of the following characters when CODE C has already been selected as the start
character.
{S {C {2 {3 {4 {{
• A special character is expressed by a combination of { and the next character.
Control character
SHIFT
CODE A
CODE B
CODE C
FNC1
FNC2
FNC3
FNC4
'{'
ASCII
HRI character
{S
Not printed
{A
Not printed
{B
Not printed
{C
Not printed
{1
Not printed
{2
Not printed
{3
Not printed
{4
Not printed
{{
{ is printed.