18 — RS-232 DCM
Procedure 18-5 To set RS-232 DCM control signals
Selecting ON or OFF for inputs configures them as ASSUMED_ON or ASSUMED_OFF.
Selecting ON or OFF for outputs configures them as FORCED_ON or FORCED_OFF.
where pp is 1 or 9, and c is 1 or 2
18.8

Data structure (asynchronous only)

The data structure of asynchronous transmission has three configurable
characteristics:
character length
number of stop bits
type of parity
Character length
Character length is the number of data bits used to transmit a character in
asynchronous transmission. Character length can be set to:
5 bits
6 bits
7 bits
8 bits (default)
18-6
CONFIG — CIRCUIT — <pp-c> ↵ — FUNCTION — CTRL_LEADS
INPUTS
DTR
ON
A character must be 8, 9, 10 or 11 bits. The number of bits
Note —
in a character is the sum of the start bit (always 1), character length (5,
6, 7 or 8), stop bits (1 or 2) and parity bit (0 for no parity or 1 for odd,
even, mark or space). For example, if the character length is set to
5 bits and the number of stop bits is set to 1, the parity cannot be set
to no parity. If this rule is broken, the relevant softkeys are not
displayed.
RTS
DSR
OFF
2902 MainStreet Technical Practices
OUTPUTS
DCD
CTS
END_TO_END
SK000504
90-2906-01