Khz Timing - Alcatel MainStreet 2902 Manual

Network termination unit
Hide thumbs Also See for MainStreet 2902:
Table of Contents

Advertisement

20 — Codirectional DCM
Procedure 20-3 To configure alarm times
where
pp is 1 or 9
time is 0.1 to 10 seconds in increments of 0.1 second
20.5

8 kHz timing

You can configure the Codirectional DCM to generate 8 kHz timing when a circuit
is disconnected. Generating 8 kHz timing after a circuit is disconnected prevents the
far end from entering the AIS No 8K alarm condition. The AIS No 8K alarm
condition is raised whenever 8 kHz timing is not on the input of a Codirectional
DCM circuit. The two circuits on the Codirectional DCM can be set for:
8 kHz timing upon circuit disconnection (8K_TIMING)
no 8 kHz timing upon circuit disconnection (NO_8K) (default)
Procedure 20-4 To configure 8 kHz timing
where pp is 1 or 9, and c is 1 or 2
* Default
20.6
All Ones alarm indication signal
An AIS All Ones alarm is raised whenever an all ones pattern is received on the input
of a Codirectional DCM circuit. The two circuits on the Codirectional DCM can be
set to:
generate all ones upon circuit disconnection (AIS) (default)
not generate all ones upon circuit disconnection (NO_AIS)
20-4
CONFIG — POSITION — <pp> ↵ — OPTIONS — ALARM_TIME
CONFIG — CIRCUIT — <pp-c> ↵ — FUNCTION — TRUNK_COND
DECLARE
<time> ↵
8K_TIMING/NO_8K*
2902 MainStreet Technical Practices
CLEAR
<time> ↵
SK000517
SK000518
90-2906-01