5.3

Installing and removing primary rate modules

Each primary rate module has a female connector that fits onto a male connector on
the Control card. The modules are secured to mounting posts on the Control card
with screws. The holes in the module should line up with the posts. If they do not,
you are installing the module in the wrong location.
There are two jumper blocks for each primary rate module on the Control card. The
jumpers need to be configured for E1 G.703 and E1 HDSL LIMs. The jumper
configurations do not affect operations for other primary rate modules.
Procedure 5-2 To install E1 G.703 or E1 HDSL LIMs
You need a #2 Phillips screwdriver to install E1 G.703 or E1 HDSL LIMs.
1
2
3
4
2902 MainStreet Technical Practices
May 2002
90-2906-01
Sl ot 2
Sl ot 1
Ensure that the power is off before inserting or
Warning 1 —
removing primary rate modules.
Electronic circuitry is easily damaged by electrostatic
Warning 2 —
discharge. Wear a properly attached antistatic wrist strap before
handling any electronic component. Handle modules by their edges.
Ensure that the unit is turned off and that the power cord is unplugged.
Open the unit.
Remove the screws from the appropriate Control card mounting posts.
Locate the jumper blocks on the Control card corresponding to the module position.
Jumper blocks J37 and J40 correspond to LIM P1; jumper blocks J41 and J44
correspond to LIM P2 (see Figure 5-3).
5 — Installing and removing modules
Figure 5-2 Opening the unit
P1
P2
R x- 1
Tx -1
R x- 2
Tx -2
ED G
I
Si g/ G nd
Li ne -1
O
Li ne -2
M od em
Te rm in
al
Al ar m
Lo op
U
St at us
1
2
D is pl ay
8975